Online commands
68 BCL 8 Leuze electronic
Parameter
<BCC type> <PS type> <Status> <Start address> <Para0L> <Para0H>
[… <Para122L>][<BCC>]
Acknowledg-
ment
’PSx’
x Status
'0' valid transmission
'1' invalid message
'2' invalid length of message
'3' invalid block check type
'4' invalid block check checksum
'5' invalid data length
'6' invalid message data
'7' invalid start address
'8' invalid parameter set
'9' invalid parameter type
Example
’PT03203305’
Address 33 (equal scans) is set to 5.
Save in RAM with reset (immediate acceptance of the change and tempo-
rary storage)
Command ’PT’