Leuze electronic webConfig tool – Extended configuration
Leuze electronic BPS 307i 66
Configuration of the resolution for position and speed measurement on the SSI interface (
OUTPUT
tab,
Preparation > SSI
)
Figure 9.7: webConfig function
OUTPUT > Preparation > SSI
Position resolution
Resolution for the position value
Speed resolution
Resolution for the speed value
Configuration of the bar code tape selection and tape value correction (
MEASUREMENT DATA
tab,
Bar
code tape
)
Bar code tape with 30 mm grid or 40 mm grid
Tape value correction
With this parameter, the deviation of the BCB from the correct millimeter scaling that arises from the
production process can be corrected.
Configuration of position detection (
DATA PROCESSING
tab,
Position
>
Detection
)
Integration depth
Number of successive measurements that the BPS uses for position determination.
Scaling free resolution
Free scaling of the output of the position values.
•Preset
A preset position value (preset value) is activated at an appropriate position.
Offset
Output value=measurement value+offset
If a preset is active, this has priority over the offset.
Error handling procedures
Parameters for the position value in case of failure.