LX218
Maximum pressure at the degassing
connection
1.1 bar
Ingress protection IP 30
Pollution degree 2
Table1:
General information
4.4.2 Data on power connections
LX218
Voltage/frequency
8200-000, 8200-002 Dry compressing pump
Oil-sealed pump
230V ±10%/50Hz
8200-001 Oil-sealed pump 115V ±10%/60Hz
8200-002 Dry compressing pump 230V ±10%/50Hz
8200-003 Dry compressing pump 115V ±10%/60Hz
8200-004 Without pump 100-230V 50/60Hz
Excess voltage category II
Current < 10 A
Energy consumption Oil-sealed pump <720 VA
Dry compressing pump <300 VA
Fuses 2 pieces, 10.0 A slow-
blowing, 250 V, Ø 5 × 20
mm
Table2:
Power connections
4.4.3 Ambient conditions
LX218
Temperature
Storage
Operation
-10 °C to +55 °C
+10 °C to +35 °C
Max. relative humidity Max. 80% up to +31 °C, decreasing to
50% at +35 °C
Use Only indoors.
Elevation up to 2000 m above sea level.
Noise level < 70 dB (A)
Table3:
Ambient conditions