Operating manual and inspection booklet
Malfunctions
3435216 193
Fault Cause Remedy
12 V power supply does not work
during the 230-V operation
Charging module in the
Elektroblock defective
Contact a specialist workshop
The supply battery is deeply
discharged
Use an external charger to charge
the supply battery
The 12 V supply does not work
during 12 V supply battery
operation
12 V main switch of the supply
battery is turned off
Turn on the 12 V main switch
The supply battery is deeply
discharged
Use an external charger to charge
the supply battery
The 40 A blade-type fuse of the
supply battery is defective
Determine the defect and
eliminate it; if necessary, consult a
specialist workshop. Then replace
the 40 A blade-type fuse of the
supply battery.
The disconnect switch of the
supply battery is turned off on the
Elektroblock
Switch on the supply battery
disconnect switch
Cut-off relay in the Elektroblock
is defective
Contact a specialist workshop
The 12 V indicator light is not
illuminated
The 12 V main switch is turned
off
Turn on the 12 V main switch
Starter or supply battery
discharged
Charge the starter or supply
battery
The disconnect switch of the
supply battery is turned off on the
Elektroblock
Switch on the supply battery
disconnect switch
Cut-off relay in the Elektroblock
is defective
Contact a specialist workshop
The 2 A blade-type fuse of the
supply battery is defective
Determine the defect and
eliminate it; if necessary, consult a
specialist workshop. Then replace
the 2 A blade-type fuse of the
supply battery
The starter battery discharges
during 12 V operation
Cut-off relay in the Elektroblock
is defective
Contact a specialist workshop