Operating manual and inspection booklet
Malfunctions
206 3435216
9.6 Refrigerator
Absorber refrigerator for operation with 12 V, 230 V and gas (option)
Fault Cause Remedy
If using a 230 V mains operation Circuit breaker has tripped Determine the defect and
eliminate it; if necessary, consult a
specialist workshop, then switch
on the circuit breaker.
230 V operating voltage too low Have a specialised workshop
inspect the 230 V system
If using a 12 V operation The 12 V power supply of the
towing vehicle is not working
Check the supply lines, e.g.
coupling connectors for damage
or contact problems
12 V operating voltage too low Have a specialised workshop
inspect the 12 V system
If using a gas operation Lack of gas Open the gas bottle valve and
quick-action valve
Connect a full gas bottle
The battery igniter is not working
(applies only to some refrigerator
models)
Press the ignition knob and rotate
approx. 90° anticlockwise, remove
the cap, remove the battery and
insert a new battery. Ensure the
battery poles are properly aligned.