Operating manual and inspection booklet
Malfunctions
3435216 195
9.2.1 Alarms on operating and control panel LT 632
Alarm Cause Remedy
The operating and control panel
LT 632 switches off on its own.
Deep discharge of the living
room battery imminent.
The battery must be charged
immediately (see above).
See also operating instructions of
Elektroblock EBL. .
"Living room battery" symbol
flashing.
If operating and control panel
LT 632 are switched on:
"Living room battery" symbol
flashing.
Deep discharge of the living
room battery imminent.
The voltage of the living room
battery has dropped below
11 V.
If operating and control panel
LT 632 are switched off:
In order to protect the battery,
the operating and control
panel LT 632 and the12 V
supply to the living room
cannot be switched on any
more.
When attempting to turn on
the operating and control
panel LT 632, the "Living
room battery" symbol flashes
and the "U" is illuminated and
the current battery voltage
blinks.
Switch off all 12 V consumers.
Charge battery:
Start engine
or
connect the 230 V mains
supply
Displayed value flashes
If operating and control panel
LT 632 are switched on an the
display of the battery voltage
"Starter battery" is on:
The battery voltage of the
starter battery has dropped
below 11.6 V.
Charge battery:
Start engine
or
connect the 230 V mains
supply