192 3435216
9.2 Electrical system
Life-threatening danger due to electric shock!
Touching live components can cause serious or fatal
injury.
• Prior to any work, switch off the electrical system
and disconnect from the mains supply.
• Switch off the ELCB.
Fault Cause Remedy
In spite of being connected to the
power supply the 230 V mains
power is not working
Power cable is not connected Connect the power cable
The 230 V circuit breaker in the
motorhome has tripped
Determine the defect and
eliminate it; if necessary, consult a
specialist workshop.
Subsequently, switch on the circuit
breaker.
The 230 V fuse at the camp site
has tripped
Have the fuse at the camp site
checked and switched on by the
groundsman
When connected to a 230 V
outlet, the starter and supply
battery batteries do not charge
Charging module in the
Elektroblock defective
Contact a specialist workshop
The 40 A blade-type fuse of the
starter or supply battery is
defective
Determine the defect and
eliminate it; if necessary, consult a
specialist workshop. Then replace
40 A blade-type fuse of the starter
or supply battery.
12 V power supply does not work
during the 230-V operation
12 V main switch of the supply
battery is turned off
Turn on the 12 V main switch
The 230 V circuit breaker in the
Elektroblock has tripped
Have the electrical system
checked by a specialised
workshop
The disconnect switch of the
supply battery is turned off on the
Elektroblock
Switch on the supply battery
disconnect switch
The 40 A blade-type fuse of the
supply battery is defective
Determine the defect and
eliminate it; if necessary, consult a
specialist workshop. Then replace
the 40 A blade-type fuse of the
supply battery.