Operating manual and inspection booklet
Malfunctions
3435216 203
9.3 Gas supply
WARNING
Danger of injury due to escaping gas!
Escaping gas can explode.
• All repair work must be performed by an
authorised gas specialist workshop.
• If gas odour is detected:
– Immediately shut down the gas supply.
– Do not operate any electric devices.
– Remove fire and sources of ignitions.
• Do not smoke.
Malfunction Cause Remedy
Gas odour or higher gas
consumption
Gas supply leaks Have a specialist workshop
inspect and repair the gas supply
system
Gas device does not function Quick-action valve closed Open the quick-action valve
Gas bottle valve closed Open the gas bottle valve
Outside temperature too low for
camping gas
Only use propane if outdoor
temperatures are low
Gas device defective Contact a specialist workshop
9.4 Hob
Malfunction Cause Remedy
No flame when igniting Gas bottle valve or quick-action
valve is closed
Open the gas bottle valve and
quick-action valve
Gas bottle empty Replace gas bottle
Flame extinguishes immediately
after the regulator is released
Warm-up period too short Keep the rotary knob depressed
for approximately 10 seconds after
ignition.
Safety pilot is defective Contact a specialist workshop
Flame extinguishes when it is
reduced
Safety pilot sensor is defective Contact a specialist workshop