Driving and parking The gas-operated devices may only be used if the gas pressure
control valve with crash sensor (optional) is installed.
Otherwise, the following instructions apply:
Prior to starting a journey, close the gas bottle valve and the
quick-action valves of the gas devices.
Do not operate gas devices when refuelling, on ferries, in
garages or car parks. Danger of explosion!
Prior to longer periods of non-use, close all gas bottle valves
and the quick-action valves of all gas devices.
After a longer period of non-use (≥ 10 months), have an
authorised workshop check the gas supply system for
tightness and functioning before prior to first use.
2.6.2 Electrical system
General The vehicle is equipped with a combined power supply system
for 230 VAC/12 V. For the connection to an external power
supply, you require a three-pole CEE connection cable (see
below).
Before travelling to foreign countries, obtain information about
the plug and connector systems used at your destination.
Adapters are available from specialised dealers.
Touching live components can cause serious or fatal injury.
Improper connection or defective electrical devices can cause fires.
Always ensure that:
External power connection Prior to connecting, ensure that the external power supply
matches the specifications of the vehicle's electrical system.
The external power supply must be protected with a residual
current circuit breaker (RCD, 30 mA).
Use only connecting cable with the following properties:
Flexible CEE rubber-sheathed cable for outdoor use
Cross-section 3 x 2.5 mm² minimum
Plug connector and coupling should each have earthing
contact
Before use, check the connecting cable, plug and coupling for
damage
The connection point must not be more than 25 m away.
When using cable drums, completely unroll the power cable;
this prevents the cable from overheating.
Lay the cable so that it does not cause a stumbling hazard;
mark the cable routing, if necessary.