Operating manual and inspection booklet
Safety
28 3435216
Electrical system and devices Connect only tested and intact devices.
Any device exhibiting defects, faults or external damages
must be immediately disconnected from the vehicle system.
Periodic testing by an electrician.
Annually for frequent use
Every three years for occasional use
Half-yearly activation of the RCD test button
Any work on the system, repairs or replacement of electrical
devices must be performed by an authorised workshop only.
Prior to starting any work on the system, switch off all
electrical consumers, such as lights, TV, radio and other
devices; disconnect the external power supply and disconnect
the supply batteries.
Check the function of the integrated residual current circuit
breaker in the fuse box at regular intervals.
Never bridge, manipulate or repair any miniature circuit
breaker or safety fuse.
Replace defective fuses only after the cause of the fault has
been identified and rectified.
Replace defective fuses only with new original fuses of the
specified amps rating.
Never cover electrical components that can generate heat
during the operation (e.g. Elektroblock). Avoid any heat build-
up.