Operating manual and inspection booklet
Camping
3435216 145
6.3.2 ALDE- heater (optional)
Liquefied gas operation
1. Select "Liquefied gas mode" at the operating unit.
2. Open the gas shut-off valve for the heater.
3. Start the heater.
When you start the heater, the system automatically ignites the
burner,
The heater is active until the set temperature has
been reached. If the flame dies within this time, the
system automatically restarts after approximately ten
seconds.
Operation with electric heater cartridge
1. Connect to a 230 V mains supply.
2. Select "Electric heating mode" and any available heating
level at the operating unit.
The heater starts automatically at 230 V.
NOTE
For a faster heating of the vehicle, operate the system
with gas and power at the same time. Electric
operation will always have priority.