Operating Manual
- Page 64 -
Instruction Display Shows
2
Type 1 then press ENTER to register 1 in From.
Type 10 then press ENTER to register 10 in To.
GROUP EDIT
ADDR: 1-10
-----y 5.Dispense Time
2.Delete 6.Offset
3.Move 7.Offset (R.E)
4.Line Speed
Select:
3
The Group Edit menu will then appear, allowing the
user to select an operation to be applied to the range of
points.
Press 1 to select Copy. Then press ENTER.
GROUP COPY
-----E 1-10
Destination:
4
The display will prompt the user to type the
destination memory address where the data will be
copied.
Press the Clear key to erase the old value, then type 11
and press ENTER to select destination memory
address number 21.
GROUP COPY
SOURCE 1-10
Destination: 11
1.Yes.No
3. Select:
5
The display will now prompt the user to confirm the
copy. Press 1 and then press ENTER to select Yes and
perform the copy.