7.2.3 Program Name
Program Name allows the user to register a name for the current program. If a program name is
registered, it will appear on the display when that program is selected in Run mode.
7.2.4 Z-axis Limit (mm)
Z-axis Limit allows the user to limit the range of the Z-axis.
Use the Z↑ and Z↓ keys to bring the Z-axis to the lowest point the Z-axis should be allowed to
travel (the highest Z-axis numeric value), then select F2 MENU (F2 KEY), 4. Z-axis Limit. (mm)
The Z-axis range of motion will be limited to the current value.
7.2.5 Initial Output Port
Initial Output Port sets the ON/OFF status of the output signals at the start of each program cycle.
Initial Output Port value is the decimal representation of 8 binary bit values controlling the 8 output
signals.
For example,
Decimal
Value
Output Status
(X = on, blank = OFF)
#1 #2 #3 #4 #5 #6 #7 #8
0
1 X
2 X
4 X
8 X
16 X
32 X
64 X
128 X