Operating Manual
- Page 65 -
7.2.1.2 Delete
To use group edit to delete addresses 10 – 25 in the current program:
Instruction Display Shows
1
Press the F2 key, then 1 to select Group Edit.
The display will prompt the user to enter the starting
memory address of the group to edit (From) and the
ending number of the group to edit (To).
GROUP EDIT
FROM: 1
TO: 1
(1 <-> 4000)
w+: All w-: End
2
Type 10 then press ENTER to register 15 in From.
Type 25 then press ENTER to register 25 in To.
GROUP EDIT
ADDR: 10-25
----------------------1.Copy
2.Delete 5.Dispense Time
3.Move 6.Offset
4.Line Speed 7.Offset (R.E)
Select:
3
The Group Edit menu will then appear, allowing the
user to select an operation to be applied to the range of
points.
Press 2 to select Delete. Then press ENTER.
GROUP DELETE
ADDR: 10-25
-----s
2. No
Select:
4
The display will now prompt the user to confirm the
deletion.
Press 1 and then press ENTER to select Yes and delete
the data.