Appendix D
9-8
Press “S” from the Controller Menu screen to access the System Setup screen.
LOOP V4200-9 === System Setup === 16:18:57 08/18/2003
>> Select System_setup Type ? *MAP PORT_BACKUP SYSTEM CLOCK
Use the arrow keys to move the cursor to SYSTEM. Then press Enter. The System Setup
(SYSTEM)screen will appear as shown below.
Move the cursor down to IP Address and key in the address of the Loop-V 4200-9. Then key in the Subnet
Mask and the Trap IP. (In our sample setup the Trap IP is the IP address of the PC.) Make sure that the
4200-9 IP address and the PC’s IP address are in the same domain
Press ESC A prompt will appear asking “Change Configuration (Y/N)? Press Y. The System Setup screen
will appear. Press ESC to return to the Controller Menu.
LOOP V4200-9 === System Setup (SYSTEM) === 16:22:39 08/18/2003
ARROW KEYS: CURSOR MOVE, Please Input: hh:mm:ss mm/dd/yyyy, BACKSPACE to edit
[System]
Time/Date :16:22:02 08/18/2003
IP Interface :ETHERNET_PORT
IP Address :192.168.100.100 Subnet:255.255.255.000 Gateway:192.168.100.206
Trap IP Address:192.168.100.206
Community Name :public
Device Name :LOOP V4200-9
System Location:8F,No. 8,Hsin Ann Rd.
Science-Based Industrial Park
Hsinchu,30077 Taiwan
System Contact :Name: FAE Tel:+886-3-5787696 Fax:+886-3-5787695
E-mail:FAE@loop.com.tw
Baud Rate : 9600 TSI_FUNC: 1:1(Bidirection)
Data Length : 8-Bits
Stop Bit : 1-Bit
Parity : NONE
XON_XOFF : XOFF
<< Press ESC key to return to previous menu >>
Press V from the Controller Menu to store. The Store/Retrieve Configuration screen will appear. Use the
arrow keys to move the cursor to “STORE” and press ENTER. A prompt will ask Store Current
Config. (Y/N)?” Press Y. You will be asked for your password. Key it in and then press ENTER. The word
“Saving….” will appear on the screen. When it disappears press ESC to return to the Controller Menu.
>> Select ? *STORE RETRIEVE
Repeat the Ping test again, only this time send the Ping signal to the Loop-V 4200-9 Ethernet Port only
To do so minimize the Loopterm screen. Go to the menu bar at the bottom of your computer screen and left-
click your mouse on the MS DOS Prompt box to bring the MS DOS Prompt screen back up into view.