ProtoMat E34/E44
Technical data
V. 1.0 | LPKF Laser & Electronics AG
19/78
2 Technical data
Operating conditions
Data
Value
Unit
Temperature range (operation)
15 to 25
°C
Temperature range (storage, transport)
15 to 35
°C
Max. humidity, non-condensing
60
%
IP Code ( IEC 60529) of the power supply unit
IP20
-
Service life
10
Years
Electrical data
Data
Value
Unit
Power supply
100 to 240
V
50/60
Hz
Output power of the power supply unit
120
W
Mechanical data
Data
Value
Unit
Dimensions (width x height x depth)
370 x 300 x 450
mm
Weight (without packaging)
15
kg
Weight (with packaging)
20
kg
Process data
Data
Value
Unit
Rotation speed range
E34: up to 30 000 (variable)
E44: up to 40 000 (variable)
min
-1
Travel speed
100 (diagonally)
mm/s
Drilling performance
100 strokes
min
-1
Collet
3.175 (1/8")
mm
Processing area with processing table (x/y/z)
229 x 305 x 5
mm
Resolution (x/y)
+/- 0.8 (0.04)
µm (mil)
Repeatability
+/- 5 (0.2)
µm (mil)
Accuracy using the reference-hole system
+/- 20 (0.8)
µm (mil)
Emissions
Data
Value
Unit
Sound pressure level LpA (EN ISO 3744)
< 70
dB (A)
Sound power level LwA (EN ISO 3744)
71 (without extraction system)
dB (A)
EMC emission class
A
-