MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting
555-661-140
Issue 1
August 1998
Page 4-57
Module Problems
Table 4–4. Board Controller Test Errors
Restoring the Module
When you are finished running module tests, be sure to restore the module. See
‘‘Restore’’ on page 4-45
.
B-Channel Loopback Test
This test verifies that specific communication paths on the MLX or 800 NI-BRI
modules are operational. If you have not read ‘‘Module Test Process’’ on page
4-34, do so.
Error Messages Corrective Action
6ORWLVQRWEXVLH GRXW Exit the test, busy-out the slot, and try again.
6ORWHPSW\RUQRWYDOLG Exit the test and try again; be sure to type the correct
slot number. Do not indicate an empty slot or the
processor (00).
)0:5QRWLQ6WDQGE\0RGH Exit the test and try again; if this error persists, record
the errors on the repair tag and replace the module
being tested.
7HVWUXQQLQJWRRORQJ Exit the test and try again; if this error persists, record
the errors on the repair tag and replace the module
being tested.
1RWLQ7(6767$1'%<PRGH Exit the test and try again; if this error persists, record
the errors on the repair tag and replace the module
being tested.
Any other error Record the errors on the repair tag and replace the
module.