MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting
555-661-140
Issue 1
August 1998
Page 2-27
Access Log
Access Log
In addition to checking the error logs, you can check the access log to help you
troubleshoot. Each time maintenance or system programming is accessed, the
event is recorded in an access log (up to the last 20 events). This information
may be useful in determining whether one of those events caused an error
detected shortly thereafter.
Reviewing the Access Log
Each event is documented by the time and date of occurrence. The station
button (
6WD) column indicates whether the event occurred from an MLX-20L
console (if so, the extension number is displayed) or from SPM (
630' if direct;
6305 if remote). The SP/M column indicates whether the event originated from
System Programming (
63) or Maintenance (0).
Scanning the Log
The last 20 events are shown, beginning with the most recently accessed event.
When you reach the end of the list, you hear a beep and all variable information
is cleared from the screen. To return to the beginning of the list, select
([LW and
then select
$FFHVV/RJ again.
Summary
To check the access log, follow the steps below.
Console Procedure Menu:
0DLQWHQDQFe→6\VWHP→$FFHVV/RJ
PC Procedure

→

→
