Conference: Cannot Add Call
Conference: Cannot Add Call
Non-local extensions are treated as outside parties for the purpose of transfer.
A non-local conference participant takes up one of the two outside calls
permitted in a conference.
NOTE:
A PassageWay Telephony Services client cannot add a non-local
extension to a conference. The user must add the conferee by using a
telephone. If a conferee is dropped, the PassageWay Telephony Services
client display does not so indicate. A PassageWay Telephony Services
client, when added to a conference, only sees information about the
conference originator, not about other conferees.
If this is not the problem, call the Lucent Technologies Helpline at 1 800
628-2888; consultation charges may apply.
DID Calls Not Completed
There are several reasons why Direct Inward Dialing (DID) calls across a
private network may not complete, either due to busy facilities or to faulty
programming. The coordinating system manager may need to address the
problem.
Possible Cause 1:
All programmed and available routes for the call are busy.
What to do: This problem solves itself when traffic decreases. Only address the
problem if it persists.
Note the extension number range for the DID destination. At the system where
the call is received from the PSTN, check that the pattern assigned to the range
includes sufficient different routes with pools (of tandem and/or PSTN facilities)
to handle the call volume. This is accomplished by checking the error for errors
4C01 (Pool Empty), 4C02 (Pool Busy), or 4C03 (Pool Busy and/or
Out-of-Service). If any of these error codes are present, check the pool index on

Table of Contents

Other manuals for Lucent Technologies MERLIN LEGEND Release 6.1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies MERLIN LEGEND Release 6.1 and is the answer not in the manual?

Lucent Technologies MERLIN LEGEND Release 6.1 Specifications

General IconGeneral
BrandLucent Technologies
ModelMERLIN LEGEND Release 6.1
CategoryConference System
LanguageEnglish

Related product manuals