EasyManuals Logo

Lucent Technologies MERLIN LEGEND Release 6.1 Maintenance And Troubleshooting

Lucent Technologies MERLIN LEGEND Release 6.1
510 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #194 background imageLoading...
Page #194 background image
MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting
555-661-140
Issue 1
August 1998
Page 4-82
800 NI-BRI Module Problems
!Interpret the test results.
If the test completes successfully, the module’s B-channels are
functioning properly. If a communication path fails, find the result code in
Table 4–7
and proceed as indicated.
!
Restore the module when all tests are completed.
When all of the lines have passed the test, the red LED remains on until
the CO reinitializes all of the lines.
Follow the procedures in Table 4–7
to examine each BRI line that has an error
and make corrections, if necessary, before rerunning the tool.
Table 4–7. NI-BRI Test Result Codes
Result
Code Description Corrective Action
2.
(Release
4.0 and
earlier)
BRI facility
provisioned with
functioning voice
and data
capabilities
No action required if voice and data functions
are expected.
&29
CO provisioning
error for voice calls
on that facility
The facility is correctly programmed and
established on Layers 1, 2, and 3. However, a
problem associated with the provisioning at
the CO for voice calls was detected.
If the facility is intended to provide voice calls,
perform the following tests and record the
results before contacting the LEC:
Outgoing Voice Call Test (page 4-94
)
Incoming Voice Call Test (page 4-95
)
Continued on next page

Table of Contents

Other manuals for Lucent Technologies MERLIN LEGEND Release 6.1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies MERLIN LEGEND Release 6.1 and is the answer not in the manual?

Lucent Technologies MERLIN LEGEND Release 6.1 Specifications

General IconGeneral
BrandLucent Technologies
ModelMERLIN LEGEND Release 6.1
CategoryConference System
LanguageEnglish

Related product manuals