MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting
555-661-140
Issue 1
August 1998
Page 4-94
800 NI-BRI Module Problems
Outgoing Voice Call Test
Place a voice call from the BRI line under test. Call either a working facility on
the system or a phone on the premises that is connected to the central office
(CO).
NOTE:
The 800 NI-BRI module must be restored (removed from the
Maintenance-Busy state) before performing this test. See ‘‘Restoring the
Module’’ on page 4-109.
!Assign the BRI line to a button on an MLX display extension.
If using a facility on the system as a destination, also assign the
destination facility to a button on another MLX display phone.
!Press the button associated with the BRI line under test.
Table 4–7. Continued
Result
Code Description Corrective Action
12767
Testing was not
performed on this
facility because no
other Layer 3
initialized facility
was available in the
time allowed for
testing.
Layers 1, 2 and 3 are established. Correct the
known problems on the other facilities and
rerun the test.
"""""
Testing was
inconclusive
because the line(s)
used to test this one
had problems.
Correct the known problems on other facilities
and rerun the test.