MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting
555-661-140
Issue 1
August 1998
Page 5-7
Checking Ports
■ A seizure of an outgoing tie trunk fails.
■ A transient error is reported. After four unsuccessful seizure attempts,
the port is marked
maintenance-busy
and the error becomes
permanent.
■ The CO fails to disconnect.
■ A transient error is reported. After two occurrences, the port is marked
maintenance-busy
and the error becomes permanent.
NOTE:
The test is not run on auto-out tie trunks.
Maintenance-Busy Programming
You can select 0DLQWHQDQFH%XV\ as a system programming option. If you do,
there is also a menu selection to include tie trunks.
Maintenance-Busy Status
See “Checking Ports” below for information about maintenance-busy status.
Checking Ports
You perform the following procedures from the maintenance terminal. By
selecting
3RUW from the Maintenance screen, you can check the
maintenance-busy status and other information for individual trunks and
extensions.