MERLIN LEGEND Communications System Release 6.1
Maintenance and Troubleshooting
555-661-140
Issue 1
August 1998
Page 4-87
800 NI-BRI Module Problems
Table 4–7. Continued
Result
Code Description Corrective Action
&2''9
(Release
4.1 and
later)
Error in LEGEND
administration of
DN and/or CO
provisioning error
for voice and data
calls on that facility
The facility is correctly programmed and
established with layers 1, 2, and 3. However,
no incoming data calls can be received.
Check that the facility is programmed with the
DN provided by the LEC.
If the facility is part of an MLHG, check if the
MLHG DN is absent. If the MLHG DN is
absent, administer it and rerun the test.
The possible cause of this error is any
combination of the causes of
&2'19 and
&2'1'.
'1
(Release
4.1 and
later)
Incorrect DN
administration
The facility is established in layers 1, 2, and 3.
Check that the facility is programmed with the
DN provided by the LEC and rerun the test. If
the error persists, contact the LEC.
If the facility is part of an MLHG, check if the
MLHG DN is absent. If the MLHG DN is
absent, administer it and rerun the test.
Continued on next page

Table of Contents

Other manuals for Lucent Technologies MERLIN LEGEND Release 6.1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies MERLIN LEGEND Release 6.1 and is the answer not in the manual?

Lucent Technologies MERLIN LEGEND Release 6.1 Specifications

General IconGeneral
BrandLucent Technologies
ModelMERLIN LEGEND Release 6.1
CategoryConference System
LanguageEnglish

Related product manuals