Unit Load Worksheet
5. Calculate the estimated unit loads.
â–  If the total is less than or equal to 54, any power supply module is
sufficient.
â–  If the total is greater than 54, continue to Step 6.
Module Qty x Unit Load = Total
008 12.0
008 MLX 13.5
008 OPT 8.0
012 8.4
016 (T/R) 12.8
100D 0.0
400 (LS) 0.0
400 EM 8.0
400 GS/LS/TTR 8.0
408 12.0
408 GS/LS 12.0
408 GS/LS-MLX 13.5
800 0.0
800 NI-BRI 0.0
800 GS/LS 0.0
800 GS/LS-ID 8.0
800 DID 8.0
MERLIN LEGEND
Mail
0.0
Total Estimated Unit Load