363-208-011 Appendix 2
NE00676-70 Local Alarm Relay Unit Installation Procedure
Issue 1.0 August 1998 11
Figure 2. LARU CABLE ASSEMBLIES
D
D
D
O
O
O
D
D
D
O
O
O
D
D
D
D
D
O
O
O
J305 (non-wiring side)
P114 (non-wiring side)
J114 (non-wiring side)
TERM 1
TERM 1
TERM
TERM 3
TERM 6
TERM 1
TERM
TERM 3
TERM 6
TERM J305 J114 P114
1 RED 18GA RED 22GA 2 RED 18GA & 22GA
2 BLACK 18GA nc nc
3 nc BLACK 22GA 2 BLACK 18GA & 22GA
4 nc BLUE 22GA BLUE 22GA
5nc nc nc
6nc nc nc
NE00676-30G1 CABLE ASSEMBLY
O
O
O
O
O
PIN 1
P253
J253 P253
9 D-SUB FEMALE AMP 5 PIN MALE
TERM FUNCT. WIRE COLOR TERM
1 CR GREEN 1
2 MJ WHITE 2
3 MN ORANGE 3
4 PMN YELLOW 4
5 GND BLUE 5
J253
NE00676-30G2 CABLE ASSEMBLY
(non-wiring side)
(non-wiring side)
O
PIN 1
4
4