LUBRICATION GRT8100 SERVICE MANUAL
9-22
Published 3/26/2018, Control # 596-05
88
Retract Cable
Sheaves
Figure 9-12
&
Figure 9-13
A
Until grease
extrudes
250 hours or 3 months
4 grease fittings
Extend Tele 2 to
38.2 Meters
(125.3 FT) so
the access
holes align with
the grease
fittings.
NOTE: Lubricate items more frequently than interval in table if environmental conditions and/or operating conditions
require.
CAUTION: Do not apply excessive pressure or force when greasing wear pads. This can cause grease fitting to separate
from wear pad. Only apply grease until resistance is felt.