Two sensors are in the both sides of a heat sink.
There are two ways of checking.
One of way, Remove either sensor and connect the test
resister. Other one, remove both sensors. And one connects
0 ohm and another connects test resistor.
The check of the thermo sensors RN69 and RN70 for Fan
uses a drier etc.
And check the resistance of a sensor. (RN69 and RN70)
Ambient temperature 20 to 30 degrees centigrade: Over 50
ohm
If overheat is detected, 2nd pin of J124 (_HEAT_DET) is led
to GND by a transistor.
Normally, it is high impedance (open-collector).
Function Test Resister Value Temperature
1 Normal 0 - 220 ohm (0 ohm) Under 110 °C
2 Heat Protection (Stand-by) Over 4.7k ohm (10k ohm) Over 110 °C