Communications Errors
If you see the following communication error (USB Disconnected) on the tablet when you are
running the machine it is caused by electrical interference or a bad tablet USB connection.
Please follow these steps to minimize electrical interference from external reloading
devices that contain motors:
• Check USB connection between tablet and Console is secure
• Install the Mr.Bulletfeeder and Dillon case feeder filter included with the system.
• Route the Dillon power cord and Mr.Bulletfeeder power cables away from tablet USB
and power cords. Do not zip tie the Dillon Power cord to the 650 case feeder pole.
• Power the Mr.Bulletfeeder & Dillon case feeder on their own surge protector if possible.
• Make sure the USB connectors are secure and away from the moving 650 components.
• Check your electrical grounds, grounding the machine to an independent true earth
ground is recommended.
In the event of this error you must clear the shell plate from all brass, rectify the situation above
that caused the error, turn on the machine, proceed with calibration, and restart your operation.
If this error occurs during machine operation and you have followed the above steps please
contact us for technical support.
Troubleshooting
Refer to the knowledge base section on our website under SUPPORT for troubleshooting
articles relating to setup and operation.