1.6.1.4 Humidity
The mechanical and electrical components are designed to operate correctly at a maximum relative humidity
level of 80% and temperatures of up to 31°C (87.8°F), decreasing linearly to a relative humidity level of 50%
at a temperature of 40°C (104°F).
1.6.1.5 Altitude
The electrical components are designed to operate correctly up to 2000 metres above sea level.
4.1.1.1 Contaminating agents
The electrical components have been adequately protected against the infiltration of solid and liquid bodies
for the intended use of the P1 and the environment that the P1 is used in.
Unless otherwise stated in the contract, the electrical components DO NOT have specific protections against
contaminating agents such as dust, liquids, acids, corrosive gases, salt, etc.
If using electrical components and the complete equipment in environments subject to such contaminating
agents contact Marposs immediately. Marposs will check the suitability of the assembly based on the
environments they are used in.
4.1.1.2 Ionising and non-ionising radiation
The electrical components ARE NOT specifically protected against radiation such as microwaves, ultraviolet
rays, lasers, X-rays.
If the P1 is exposed to radiation, additional measures must be implemented to prevent to incorrect operation
of the components and their early deterioration.
4.1.1.3 "Normal” environmental lighting
The installation procedure must be carried out under “normal” lighting conditions, i.e. without dazzling the
operators with too much light or causing them to strain their eyes in insufficient lighting.
The P1 installers must comply with the minimum requirements set out by the applicable laws in the
respective countries in terms of natural and artificial lighting of the premises.
If there is poor lighting in the work place the operator must use portable lighting equipment.
4.1.2
Removing the P1 from its packaging
Marposs has not stipulated any special equipment to be used when removing the P1.
ATTENTION
Handle with care: Static sensitive components.
Before accessing the front panel, operators must make sure they have eliminated any
accumulated electrostatic charges by touching a metallic surface that is
connected to the
building earth system.