Instruction Manual
Instruction Manual
13
2.2
P1 Safety information
2.2.1
Authorised and unauthorised use
2.2.1.1 Intended use
The P1 has been designed and built to be installed on automatic machines such as grinders in order to
manage the Marposs measurement heads used for in-process part dimension controls.
[
NOTE
Any use that differs from the use described above shall be considered unauthorised.
Any modification altering the P1 in terms of safety and risk prevention may
only be made by
Marposs, which will certify equipment compliance with safety standards.
Therefore, modifications or maintenance operations not covered by the technical documentation
shall be considered arbitrary.
Marposs declines all responsibility in case of any non-compliance with the above.
1.2.4.5 Unauthorised usage
Do not use the P1:
1. in environments with the risk of explosion or fire;
2. in environments where contaminants such as acids, corrosive gases, salts etc. are present (see
para. 4.1.1.1 and 1.5.1.2;
3. in environments where the P1 may be exposed to radiation such as microwaves, ultraviolet rays,
lasers, X rays, etc. - see para. 1.5.1.3
Never:
4. modify the original P1 settings;
5. connect the P1to power supplies having specifications that differ from those described in this
manual;
6. use components for uses not set out by Marposs.
1.2.5
Risks, protection, warnings and cautions
1.2.5.1 Residual risks
Electrical wiring
ELECTRIC SHOCK RISK
When looking for faults with live parts there is the risk of electric shock caused by the direct or
indirect contact (suitable clothing must be used).
It is important to remember that incorrect actions by the operator can generate residual risks.
Due to the type of construction it is not possible to guarantee absolute safety against risks and dangers
generated by:
Operator carelessness,
Non-compliance with the information and indications contained in these instructions,
Deliberately tampering with the P1 and/or its safety devices,
Tampering with the fixed and movable safety panels.