EasyManua.ls Logo

marposs P1 - Machine Logic I;O Connection

Default Icon
43 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Instruction Manual
28
P1
Instruction Manual
6.4
I/O connection to machine logic unit
Connect the I/O to the machine logic as shown in the following figures:
Use the connector provided to connect the I/O. The maximum power cable cross section compatible with this
connector is 0.5 mm
2
[
NOTE
The “SINK current” input is driven by a switch or limit switch connected between the input itself
and the positive pole of the machine I/O power supply. The SOURCE input is driven by a switch
or limit switch connected between the input itself and the negative pole of the machine I/O power
supply.
SOURCE current output /SINK current input connections
Figure 9 Example showing Source Current Output/Sink Current Input connections
I/O with SINK current inputs and SOURCE current outputs
Input circuits (SINK current 24 V d.c.)
I
I
(at 24 V)
7 mA typ.
V
I
(ON)
(15 - 30) V (I
I
= 4 - 10mA)
V
I
(OFF)
(3 - 5) V
Output circuits (SOURCE current 24 V d.c.)
30 V d. c max.
I
O
(ON)
50mA max. with resistive load
Vdropout(ON)
3 V typ. (Io = 50 mA)
I
LEAKAGE
(OFF)
100µA max
[
NOTE
The SINK current type inputs connection features specifications that are compatible with the
"TYPE 1" digital inputs as defined in the Standard EN61131-2.

Table of Contents