THE REPETITION COUNTER IS BLANK OR IS NOT COUNTING MOVEMENTS
POSSIBLE CAUSES
1) The rep counter battery is dead or disconnected.
2) The rep counter is unplugged from the repetition sensors.
3) The magnet is missing or mispositioned.
4) The repetition sensors are faulty or mispositioned.
5) The rep counter is faulty.
SOLUTION
1) Remove the 4 screws holding on the aluminum wing and top cover. Check that the battery for the rep counter is firmly seated and has a
charge. Replace the battery if needed.
2) Check the connection of the wiring coming from the repetition sensors to the rep counter (Figure A).
3) Check that the magnet is present and in a position to be read by the repetition sensors (Figure B). The magnet should be slightly off the
center of the sensors.
4) If the rep counter displays a value, but is not counting repetitions, check the position of the sensors. The sensors should be positioned
depending on the model according to the chart on the following page. If the rep sensors are positioned correctly and still not reading, replace
the repetition sensors (Figure C).
5) If the repetition sensors and battery have been replaced and the issue is still present, replace the rep counter.