107 Matrix VISIONPRO System Manual
How to configure
The functioning of this feature is controlled by three parameters, 'Barge-In', 'Privacy from Barge-In' and 'Barge-In
Timer'.
Barge-In and Privacy from Barge-In
First decide which of the stations are to be allowed Barge-In and the stations that are to be protected against
Barge-In. Accordingly enable/disable the features Barge-In and Privacy from Barge-In in the Class of Service of the
station users.
Refer the topic “Class of Service (CoS)” and “Privacy” for details.
Barge-In Timer
It is the time after which the caller gets connected to the called party using Barge-In.
To configure,
• Enter SE mode.
•Dial 3016-Seconds
Where,
Default: 010 seconds.
Valid Range: 000 to 255 seconds.
• Exit SE mode.
How to use
When dialed station is busy,
•Dial 3 on Busy Tone.
• You get Ring Back Tone (RBT). The called person gets beeps.