Matrix VISIONPRO System Manual 132
To configure different timers applicable to different CPTs,
• Enter SE mode.
• To configure the Dial Tone Timer, dial,
3001-Seconds
Where,
Range: 001 to 255 seconds.
Default: 007 seconds.
• To configure the Ring Back Tone Timer, dial,
3002-Seconds
Where,
Range: 001 to 255 seconds.
Default: 045 seconds.
• To configure the Busy Tone Timer, dial,
3003-Seconds
Where,
Range: 001 to 255 seconds.
Default: 007 seconds.
• To configure the Error Tone Timer, dial,
3004-Seconds
Where,
Range: 001 to 255 seconds.
Default: 030 seconds.
• To configure the Feature Confirmation Tone Timer, dial,
3005-Seconds
Where,
Range: 001 to 255 seconds.
Default: 003 seconds.
• To configure the Programming Inter Digit Timer (for the Programming Tone), dial,
3006-Seconds
Where,
Range: 001 to 255 seconds.
Default: 015 seconds.
• To configure the Programming Error Tone Timer, dial,
3007-Seconds
Where,
Range: 001 to 255 seconds.
Default: 003 seconds.
• To configure the Programming Confirmation Tone Timer, dial,
3008-Seconds
Where,
Range: 001 to 255 seconds.
Default: 003 seconds.
• Exit SE mode.