Matrix VISIONPRO System Manual 66
To enable/disable Call Disconnect Tone for a trunk, dial,
3133-1-Trunk-Code
Where,
Trunk is the software port number from 0 to 2.
Default code value is 0.
To enable/disable Call Disconnect Tone for all trunks, dial,
3133-*-Code
To set the Call Disconnect Tone Frequency for a trunk, dial,
3134-1-Trunk - Frequency 1 - Operator - Frequency 2
Where,
Trunk is the software port number from 0 to 2.
Frequency 1 and Frequency 2 can be from 0000 to 4095Hz
Default Frequency 1, Operator and Frequency 2
To set the Call Disconnect Tone Frequency for all the trunks, dial,
3134-*-Frequency 1 - Operator - Frequency 2
To set the Call Disconnect Tone Cadence for a trunk, dial,
3135-1-Trunk- Index - ON Time - OFF Time
Where,
Trunk is the software port number from 0 to 2.
Index is from 0 to 3.
ON Time and OFF Time can be from 0000 to 4095msec
Default Index and ON Time - OFF Time
To set the Call Disconnect Tone frequency for the trunks, dial,
Code
Meaning
0 Disable
1 Enable
Operator
Meaning
0 None
1 Summation (+)
2 Modulated (*)
Frequency 1 Operator Frequency 1
0400Hz 0 0000Hz
Index 0 Index 1 Index 2 Index 3
ON Time - OFF Time ON Time - OFF Time ON Time - OFF Time ON Time - OFF Time
0750 msec - 0750 msec 0750 msec - 0750 msec 0000 msec - 0000 msec 0000 msec- 0000 msec