EasyManua.ls Logo

Menvier Security TS700 - Factory Default Parameters

Menvier Security TS700
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Factory Default Parameters
Engineer's code 1234
Master User
code
5678
Panel and
Remote Outputs
1 2 3 4 5 6 7 8
Walk Test Courtes y
Light
Switched
12V
Detector
Reset
Code
Accepte
d
Code
Accepte
d
Code
Accepte
d
Code
Accepte
d
Digicom Outputs
& Channels
1 2 3 4 5 6 7 8
Fire PA Alarm Set Eng on
Site
Bell On Tamper Sec ond
Alarm
Detection
Circuits
01: Final Exit 02: Night (access) 03-06: Night 07: Exit Terminator
08: PA Audible 09: Final Exit 10: PA Audible 11-16:Not Used
System Timers
0 1 2 3
ACPO Delay
0 seconds
No Re-arms
0
Settling Time
07 seconds
Di gicom Del ay
0 Seconds
4 5 6 7
Exit Time
30 Seconds
Entry Time
30 Seconds
Bell Duration
20 Minutes
Bell Delay
0 Minutes
8 9
Double Knock
0 Seconds
Test T im e
14 Days
Setting Modes
Full Set
Final Exit
Part Set A
Timed Exit
Part Set B
Timed Exit
Part Set C
Timed Exit
Reset Algorithm 004
System
Configuration
0 1 2 3
Bell output is SAB User 1 has access
to all user menus
Fire signalled at all
times
24 Hour cir cuits are
audible
4 5 6 7
bell is delayed for
30 seconds in part
set
Alarm output is
cleared on reset
Setting with line fault
or mains failure is
allowed
System reset by user
8 9
Continuous entry
and exit to nes
Engine er code only
for access to
engineer menus
Tabl e 1. Factory Default Parameters
15
TS700 Instal lation Manual S ystem Installation