Programming procedure
1. First, imagine the system is fully set. When "Part-set Code A" is entered certain circuits are
required to be "Omitted" whilst others remain "Armed". Create a table listing the circuits that
are to be "Omitted" (O) when " Part-set Code A " is entered. The circuits that will not be omitted
must therefore remain "Armed" (A ). Then im agin e the system i s fully set again and repeat for
"P art-set Codes" B and C.
Circ uit No . Location G roup A Group B Group C
01 W orkshop PIR (1) A O A
02 W orkshop Internal Door A O A
03 W orkshop PIR (2) A O A
04 Sales Internal Door O A A
05 Canteen Door O O O
06 Canteen PIR O O O
07 Stores Intern al Door A A O
08 Sales PIR O A A
09 Sales Office PIR O A A
10 Sales Entrance Door O A A
11 W orkshop Entrance Door A O A
12 W orkshop PIR (3) A O A
13 Stores Entrance Door A A O
14 Stores PIR A A O
2. From the above table assign circuits 01 - 14 as "Armed" or "Omitted" for each "Part-set
G roup", see page 24 for full details.
3. Program the setting mode for each "Part-set Group", see page 20 for full details.
4. Program each "Part -set Code" with a four digit passcode, refer to the "User Operating
Instructions".
+
Ifacirc uitis"Omitted"inmorethanone"Part-setGroup"(circuits05and06inourexample)it
will only be armed when all "Part-set Groups" are set. Using our examp le, if th e sy stem is
unset and "Part-set Code A" is entered, the exit procedure is started and at the end of the
exit proce dure circui ts 04, 08, 09 and 10 will be armed. The canteen detection circuits 05
and 06 will remain unarmed until "Part-set Group" B and C are set (s ystem full-set).
29
TS700 Instal lation Manual Appendices