6. Select new setting mode b y pressing:
1 for Final Exit
2 for Exit Terminator
3 for Timed Exit
0 to `toggle' between all t hree options
7. W hen the display shows the required setting press [ to accept.
The display will return to step 3. Repeat steps 4 to 7 for the
rem aining sett ing groups.
8. Press ] to return to "Engineer Menu 1".
+
When using part set codes to set areas, the first area that is s et willfollow the setting mode
defined by that area. Any subs equen t areas will always use the timed exit method.
System Print
A print-out of all system parameters may be obtained so that a permanent record of the system
program details may be kept.
1. Ensure that "Engineer M enu 1" is selected.
2. Press 7 to select the System P rint option.
3. The display w ill show the line that is being printed (Ln01).
4. Press ] to stop printing and return to "Engineer Men u 1" .
Remote Reset Algorithm
W hen the system requires a n Engineer Reset this may be over ridden by using the Remote Reset
facility. To provide a dditional security the w ay in which the "Reset Code" is generated c an be
sele cted to be o ne of 199 algo rithms (default=004).
1. Ensure that "Engineer M enu 1" is selected.
2. Press 8 to select the Reset Algorithm option.
3. The display w ill show the current setting.
4. Enter the new number and press [ to accept.
System Co nfiguration
There are ten system configuration options which ar e shown in Ta ble 6.
1. Ensure that "Engineer M enu 1" is selected.
2. Press 9 to select the System Configuration option.
3. The display w ill show: con.-
4. Enter the required configuration numb er 0 to 9.
5. The display will show the curr ent setting. Press 0 to "tog gle"
between YES and NO. Press [ to accept.
6. The display will return to step 3. Repeat steps 4 to 6 for the
rem aining system config uration op tions .
7. Press ] to return to "Engineer Menu 1".
21
TS700 Instal lation Manual Programming
Ln01
Press ESC to cancel printing.
004
En ter new number 000 - 199 .
con.-
En ter configuration number 0- 9
(see Tab le 6).
YES