2
Settli ng Time 0-199 sec When setting the system by "FinalExit"or " Exit Terminator",detectorsthat are
on the exit route sometimes take 3-4 seconds to settle after activation. The
delay programmed in this timer is used to allow these detectors to settle
before the system or area is set.
3
Digicom Delay 0-199 sec Wh en the system is part-set the communication of an ala rm signal to the
cent ral station may be delayed by the value set in this timer.
4
Exit Time 0-1 99 sec This timer sets the delay between the us er initiating the exit procedure and
the s ystem(orarea)actually S ett ing.Ifduringtheexittimean ExitTerminator
circuit is activated the exit time is c ancelled and the s ystem se ts
imm ediately.
5
Entry Time 0-199 sec The ti me allowed for entering the protected premis es vi a the entry ro ute
when th e system is (Part) Set . The time is allocated to two entry period s. A
warning isgiven if thefirstisexceeded andafullalarm oc cursifthe second
is exceeded.
6
Bell Duration 0-199 min The duration time of the bell and sounders when an alarm occur s.
7
Bell Delay 0- 199 min This timer delays the activation of the bell output and internal sounders.
8
Double Knock 0-199 sec Th is is the Doub le Knock time window in which either:
Two circuit activation must occur within this time to generate an alarm
condition. Or the circuit must remain active for the whole duration of this
time to gen erate an alarm condition. This w ill only apply to circuits with the
Double Knock attribute
9
Test Time 0- 30 days This timer varies the number of days that T est attribut e may be applied to a
circuit. If the tim e is s et to 000 then circuits will remain on test until the "Test"
attribute is removed.
Tabl e 5b. System Time rs
Setting Modes
The system m ay be set by one of the following modes:
Final Exit - The system or area will set when the "Final Exit" circuit is activated and after
the "Settle Time" has expired.
Exit Terminator - The system or area will set wh en the "Final Exit" circuit i s activated, the "Exit
Terminator" button is pressed and after the "Settle Time " has expire d.
Timed Exit - The system or area will set w hen the "Exit Time" has expired or if the "Exit
Terminator" button is pressed.
The sett ing mode for full-set, part-set group s A, B and C are programmed as follows:
1. Ensure that "Engineer M enu 1" is selected.
2. Press 6 to select the Setting Modes option.
3. The display w ill show: S.BY-
4. Select set tin g group by pressing:
0 for fu ll-set
A for part -set group A
B for part -set group B
C for part -set group C
5. The display w ill show the current setting mode.
20
Pr ogramming TS700 Instal lation Manual
S.BY-
En ter setting group 0,A,B or C.
F-FE
En ter setting mode 1,2,3 or 0.