Print System Log
A printer may be connected to produce a print-out of the last 200 s ystem events.
1. Ensure that "Engineer M enu 2" is selected.
2. Press 7 to select the Print Log option.
3. Enter the number of events to be printed.
4. Press [ to start printing. To sto p printing select th e menu a gain
and enter 000 as the number of even ts to be pri nted.
Co nfigure Part-Set Groups
W hen the system i s part-set certain circuits are omitted. This op tion al lows the e ngineer to select
those circuits to be omitted when part-set A or B or C is selected.
1. Ensure that "Engineer M enu 2" is selected.
2. Press 8 to select the Part-Set Groups option.
3. Select t he part-set group A or B o r C.
4. Circ uit s will be di splayed as O(Omitted) or A(Armed). Press 0 to
cha nge ("toggle " action).
5. Press [ to ac cept displayed status (high tone) and go to next
ci rcuit. Circuits may be selected by number.
6. Press ] to r eturn to step 3 and ] again to return to "Engine er
Menu 2".
View System Lo g
The time, date and nature of the last 200 events on the system may be viewed starting with the
most re cent event.
1. Ensure that "Engineer M enu 2" is selected.
2. Press 9 to select the View Log option.
3. The most recent event will be displayed (see T able 7)
4. Press A to scrollback and C to scrollforward.PressB toshow the
time of the event (first press), the date (second pr ess) the time in
minutes and seconds (t hird press).
5. Press ] to abandon.
Reset Master User 1
Thisoptionallowstheengineer to resetthemaster userpasscode backto thefactory de faultcode
`5678'.Thisfeatureisusefulwhenthe masteruserhasforgotten theirpasscodeorhasinadvertently
cha nged it.
1. Ensure that "Engineer M enu 2" is selected.
2. Press 0 to Reset User 1.
24
Pr ogramming TS700 Instal lation Manual
CA.01
Log event showing `Circuit
Alarm 01'. Press A to scroll back
or C to scroll forward. P ress B to
view time and date.
01-A
Circuit 01 will remain Armed.
Press 0 to cha nge.
01-O
Circuit 01 will be Omitted .
Press ENT to accept.
PS -
En ter part-set group A, B or C.
---
En ter the number of e vents to
be p rinted. Press ENT t o start.