Menu System
When you first enter the Menu system by pressing the Enter key, you will see the
following Main Menu:
Feeder Control…
Calibration…
Warnings…
Faults…
Display Settings…
Basic Setup…
Advanced Setup…
Reset Totals…
DNA Key…
Diagnostics…
Drag Chain Control…
Note: Not all the of the above entries will necessarily appear in the menu, depending on
how the controller is configured (see Advanced Set-up > Configuration ).
Feeder Control
(Main Menu)
Note: The items presented in the Feeder Control menu will vary depending on the
current control method and source. Also “Feeder Control” only appears in the Main
Menu if “Feeder Control” is configured (see Main Menu > Advanced Set-up >
Configuration).
The following is a list of all Feeder Control items and their functions:
Start [Stop] Feeder…
Setpoint…
Jog Forward
Jog Reverse

Table of Contents

Other manuals for MERRICK Genetix

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MERRICK Genetix and is the answer not in the manual?

MERRICK Genetix Specifications

Operating Environment IconOperating Environment
maximum ambient temperature50°C (122°F)
minimum ambient temperature-10°C (14°F)
Power IconPower
supply voltage24 VDC +/- 1V
power consumption8W nominal, 12W maximum
power dissipation5W nominal, 10W maximum
Loadcell Inputs IconLoadcell Inputs
excitation voltage5 VDC
excitation current300mA (max)
Tachos IconTachos
supply voltage5 VDC
supply current400mA, maximum (total)
Analog Inputs IconAnalog Inputs
input impedance (current input)200 ohms
input impedance (voltage input)100Kohms
Digital Inputs IconDigital Inputs
input impedance at 24 VDC7.5 KΩ
input impedance at 120 VAC64 KΩ
input impedance at 240 VAC120 KΩ
Digital Outputs IconDigital Outputs
contact ratings (AC)5A, 250 VAC
contact ratings (DC)5A, 30 VDC
External Mechanical Totalizer IconExternal Mechanical Totalizer
contact ratings (AC)120mA, 240 VAC
contact ratings (DC)120mA, 24 VDC