Speed
The following settings are available for Speed limits:
High Belt Speed
Low Belt Speed
High Belt Speed Delay
Low Belt Speed Delay
High Belt Speed
If the actual belt speed exceeds this limit for duration longer than the High Belt
Speed Delay value (see below) then the logical output “High Belt Speed” is set.
This limit is set in units of belt speed.
Low Belt Speed
If the actual belt speed drops below this limit for duration longer than the Low
Belt Speed Delay value (see below) then the logical output “Low Belt Speed” is
set. This limit is set in units of belt speed.
Note this limit is only active under the following conditions:
Feeder Control is enabled (see Main Menu > Advanced Setup >
Configuration > Feeder Control) and the belt is commanded to run.
Feeder control is not enabled and the logical input “Belt Running” is on.
High Belt Speed Delay
This value provides a delay for the High Belt Speed limit, in order to prevent
nuisance alarms. The belt speed must remain above the limit value for duration
as long as this delay value for the logical output to be set. This delay value is
set in seconds.
Low Belt Speed Delay
This value provides a delay for the Low Belt Speed limit, in order to prevent
nuisance alarms. The belt speed must remain below the limit value for duration
as long as this delay value for the logical output to be set. This delay value is
set in seconds.
Setpoint
The following settings are available for Setpoint limits:
Note: The following setpoint limits will appear in the menu only if Feeder
Control is enabled (see Main Menu > Advanced Setup > Configuration >
Feeder Control ).