Start [Stop] Feeder
If Local control has been selected for the control Source (see Main Menu > Advanced
Set-up > Feeder Control > Source), this menu item allows you to start and stop the
feeder. If the feeder is not running, this item will read “Start Feeder”. If the feeder has
already been started, this item will read “Stop Feeder”.
If either “Network” or “Remote” have been selected as the control source, then you
will not have local control over starting and stopping, and this menu item will read
“Remote Start/Stop”.
If “Manual” has been selected (see Main Menu > Advanced Set-up > Feeder Control
> Control) then this will allow you to start and stop the feeder with few restrictions.
This mode is normally used only for maintenance or initial set-up of the feeder.
Setpoint
If Local control has been selected for the control Source (see Main Menu > Advanced
Set-up > Feeder Control > Source), this menu item allows you to enter and/or change
the current Setpoint. Highlighting this item and pressing the Enter key will bring up the
Numeric Data Entry screen allowing you to enter the desired setpoint. This value is
entered in units of Feedrate if the control method has been selected as “Rate
Control”, units of Speed if the control method has been selected as “Speed Control”,
or units of percent if in Manual (“Open Loop”) (see Main Menu > Advanced Set-up >
Feeder Control > Method). If in Manual control (see above), this value will be entered
in percent.
If either “Network” or “Remote” have been selected as the control source, then you
will not have local control over Setpoint, and this menu item will display the current
Setpoint (as received from the Remote source). You may not select the item to
change it.
Jog Forward
This menu item allow you to run the feeder forward briefly, only as long as the Enter
key is pressed. You must be in Manual control for this option to be available (see
above). Also “Jog OK” must be enabled (see Main Menu > Advanced Set-up >
Feeder Control > Settings).
Jog Reverse
This menu item allow you to run the feeder backward briefly, only as long as the
Enter key is pressed. You must be in Manual control for this option to be available
(see above). Also “Jog OK” must be enabled (see Main Menu > Advanced Set-up >
Feeder Control > Settings), and “Belt Reversible”. Note: There is a settable parameter
for a delay between running the belt forward and running the belt backward (see Main
Menu > Advanced Set-up > Feeder Control > Settings > Numeric Data). This is to
prevent damage to the motor or motor contactor.

Table of Contents

Other manuals for MERRICK Genetix

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MERRICK Genetix and is the answer not in the manual?

MERRICK Genetix Specifications

Operating Environment IconOperating Environment
maximum ambient temperature50°C (122°F)
minimum ambient temperature-10°C (14°F)
Power IconPower
supply voltage24 VDC +/- 1V
power consumption8W nominal, 12W maximum
power dissipation5W nominal, 10W maximum
Loadcell Inputs IconLoadcell Inputs
excitation voltage5 VDC
excitation current300mA (max)
Tachos IconTachos
supply voltage5 VDC
supply current400mA, maximum (total)
Analog Inputs IconAnalog Inputs
input impedance (current input)200 ohms
input impedance (voltage input)100Kohms
Digital Inputs IconDigital Inputs
input impedance at 24 VDC7.5 KΩ
input impedance at 120 VAC64 KΩ
input impedance at 240 VAC120 KΩ
Digital Outputs IconDigital Outputs
contact ratings (AC)5A, 250 VAC
contact ratings (DC)5A, 30 VDC
External Mechanical Totalizer IconExternal Mechanical Totalizer
contact ratings (AC)120mA, 240 VAC
contact ratings (DC)120mA, 24 VDC