value for duration as long as this delay value for the logical output to be set.
This delay value is set in seconds.
Min Spd Demand Delay
This value provides a delay for the Min Belt Speed Demand limit, in order to
prevent nuisance alarms. The belt speed demand must remain below the limit
value for duration as long as this delay value for the logical output to be set.
This delay value is set in seconds.
Load Cells
(Main Menu > Advanced Setup > Load Cells)
Selecting this menu item, you will be presented with the following menu:
Function…
Settings…
Numeric Data…
Function
The following menu lists all the available functions for the load cell functionality.
Note: Some functions require two load cells and so will only appear if two load
cells have been configured (see Main Menu > Advanced Setup > Configuration >
Load Cell n)
First Only
Second Only
Both
Auto Bypass
Inferred Load
Analog Input
From Network