EasyManua.ls Logo

MG 47 Series - Input Specifications

MG 47 Series
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10447LHZ EM-9517-B Rev.10
MG CO., LTD. www.mgco.jp
5-2-55 Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
INPUT SPECIFICATIONS
Input voltage Max. 300 V (conformance range 50 – 300 V)
Overload capacity 450 V for 10 seconds, 360 V continuous
Measuring range Input type: H50 45 – 55 Hz
Input type: H60 55 – 65 Hz
Input type: H55 45 – 65 Hz
Input type: H400 350 – 450 Hz
Input type: HF 10 – 500 Hz
Operational range Input type: H50 40 – 60 Hz
Input type: H60 50 – 70 Hz
Input type: H55 40 – 70 Hz
Input type: H400 300 – 500 Hz
Input type: HF 5 – 600 Hz
Input burden 0.5 VA
OUTPUT SPECIFICATIONS
DC output DC current Load resistance
(output range)
4 – 20 mA DC: ≤ 550 Ω
0 – 20 mA DC: ≤ 550 Ω
Operational range -5 – +105%
DC voltage Load resistance
(output range)
0 – 10 V DC: ≥ 10 kΩ
0 – 5 V DC: ≥ 5000 Ω
1 – 5 V DC: ≥ 5000 Ω
-10 – +10 V DC: ≥ 10 kΩ
Operational range -5 – +105%
Alarm output Relay contact
Rated load: 250 V AC @ 3 A (cos ø = 1)
30 V DC @ 3 A (resistive load)
Maximum switching voltage: 250 V AC, 30 V DC
Maximum switching power: 750 VA, 90 W (resistive load)
Minimum load: 5 V DC @ 10 mA
Mechanical life: ≥ 5 × 10
6
cycles (rate 180 cycles/min.)
INSTALLATION
Power consumption AC power 100 – 240 V AC Operational voltage range 85 – 264 V AC, 50/60 Hz
Approx. 6.5 VA
DC power 24 V DC Operational voltage range 24 V DC ±10%
Ripple 10% p-p max.
Approx. 3 W
110 V DC Operational voltage range 85 – 150 V DC
Ripple 10% p-p max.
Approx. 3 W
Operating temperature -10 to +55°C (14 to 131°F)
Operating humidity 30 to 90% RH (non-condensing)
Mounting Panel ush mounting
Weight 300 g (0.66 lb)

Table of Contents