14. Reconnect the machine function if disconnected earlier.
15. Start the prime mover, checking to ensure the pump remains in neutral.
16. Check for forward and reverse machine operation, with the prime mover at normal operating speed.
Charge pressure may decrease slightly during forward or reverse operation.
17. Continue to cycle slowly between forward and reverse for at least five minutes.
18. Shut down prime mover.
19. Remove gauges. Replace plugs at the gauge ports.
20. Check reservoir level. Add filtered fluid if needed.
The motor/transmission is now ready for operation.
Service Manual H1B 060/080/110/160/250 Bent Axis Motors
Initial startup procedures
32 11024924 • Rev CB • February 2015