EasyManua.ls Logo

Miele CM6 - Fault Repair; F1 - Short Circuit in Heater NTC

Miele CM6
63 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Information
21
CM6
Figure 001-18: Drip Tray Present Switch
It is located on the left side inside the appliance and is actuated by the pin on the drip
tray (Figure 001-18, Item 1).
The drip tray present switch can be tested in service mode; see Section 001-4.4.
3 Fault Repair
3.1 F1 - Short Circuit in Heater NTC (R30-14)
Symptom:
Electronic registering an NTC temperature > 200°C or resistance < approx. 430.
Cause:
NTC short-circuited.
Remedy:
1. Check the NTC wiring.
2. Replace defective plugs and/or wiring.
3. Test the NTC in service mode; see Section 001-4.4.
Note:
NTC resistance values should be
100k at 25°C (77°F),
5.5k at 100°C (212°F) and
1k at 160°C (320°F).
4. Check the NTC resistance at different temperatures and compare to the
values given above.
5. Replace the NTC, if necessary; see Section 001-4.20.

Table of Contents