EasyManua.ls Logo

Miele CM6 - F82 - Heater Too Hot

Miele CM6
63 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Information
28
CM6
Heater NTC (R30-14) defective.
Remedy:
1. Check plugs and wires.
2. Replace defective plugs and wires as necessary.
3. Test the NTC in service mode; see Section 001-4.4.
Note:
NTC resistance values should be
100 at 25°C (77°F),
5.5 at 100°C (212°F) and
1k at 160°C (320°F).
4. Check the NTC resistance at different temperatures and compare to the
values given above.
5. Replace the NTC, if necessary; see Section 001-4.20.
Cause:
Heater fuse (1F8, 2F8) has blown. An overshoot can blow one of the fuses on the
heater.
Remedy:
Replace both fuses and the NTC (since the NTC may also be damaged); see Section
001-4.20.
Cause:
Heater (R1) defective.
Remedy:
1. Check plugs and wires.
2. Replace defective plugs and wires as necessary.
3. Test the heater in service mode; see Section 001-4.4.
4. Replace the heater, if necessary; see Section 001-4.20.
3.15 F82 - Heater (R1) Too Hot
Symptom:
Heater temperature higher than 170°C for 120 s.
Cause:
Heater NTC (R30-14) defective.
Remedy:
1. Check plugs and wires.
2. Replace defective plugs and wires as necessary.
3. Test the NTC in service mode; see Section 001-4.4.
Note:
NTC resistance values should be
100 at 25°C (77°F),
5.5 at 100°C (212°F) and
1k at 160°C (320°F).
4. Check the NTC resistance at different temperatures and compare to the
values given above.

Table of Contents