Installation
*INSTALLATION*
124
Electrical connection
The dishwasher is supplied with a mains
connection cable with moulded plug
ready for connection to an earthed
socket.
The socket must be easily accessible
after the dishwasher has been installed.
If the switch is not accessible after
installation, an additional means of
disconnection must be provided for all
poles.
Risk of fire from overheating.
Connecting the dishwasher to a
multi-socket plug adapter or to an
extension lead can overload the
cable.
Do not use an extension lead or
multi-socket plug adapter.
The electrical installation and all
electrical work must be carried out by a
suitably qualified and competent person
in strict accordance with national and
local safety regulations. For extra safety,
it is advisable to install a residual
current device (RCD) with a trip current
of 30 mA. Ensure power is not supplied
to the appliance until after the
installation has been completed.
Connection should be made via a
suitable switched socket.
If the mains connection cable is
damaged, it must only be replaced with
a specific mains connection cable of the
same type (available Miele). For safety
reasons, such replacement may only be
carried out by a suitably qualified and
competent technician or by a Miele
authorised service technician, in order
to avoid a hazard.
For technical data, see the data plate
located on the right side of the door.
Compare this information with the data
of the on-site electrical connection.
If in any doubt, consult a qualified
electrician.
Temporary or permanent operation with
a self-sufficient or non-mains
synchronous energy supply system (e.g.
isolated networks, back-up systems) is
possible. A requirement for the
operation is that the energy supply
system complies with all current local
and national requirements that apply to
stand-alone, solar and/or battery
systems.
The protective measures provided in the
domestic installation and in this Miele
product must also be assured in their
function and operation in isolated
operation or in non-mains synchronous
operation, or replaced with equivalent
measures in the installation.