Technical Information
14
KF 18xx/19xx
Condenser
fan (M2/1)
Evaporator
fan, freezer
(M2/3)
Evaporator
fan,
refrigerator
(M2/4)
Air flap motor
(M28, M32)
Voltage [V] 12 (DC) 120 120 120
Power rating [W] 2.6 3.4 3.4 2.8
Resistance [kΩ] 0.06 4.2 4.2 5.1
Current [A] 0.2 0.03 0.02 0.02
Frequency [Hz] 60 60 60
Speed [rpm] 2000 1650 1650 6
Table 030-5: Other Component Specifications
Water inlet
valve (Y63)
Transformer
(T1)
Icemaker
heater (R17/1)
Side-wall heater
(R17/11)
Voltage [V] 120 120 120 120
Power rating [W] — 60 200 27
Resistance [kΩ] 1.08 0.24 0.07 0.5
Current [A] 0 0.5 0.7 0.2
Frequency [Hz] 60 60 60 60
Table 030-6: Other Component Specifications
CC compressor,
refrigerator (M16/1)
CC compressor,
freezer (M16/2)
Voltage [V] 115 115
Power rating [W] — —
Resistance [kΩ] — —
Current [A] — —
Frequency [Hz] 50–60 50–60
Table 030-7: Compressor Specifications
Temperature limiter (F1)
°F °C
Switches on at 158 70
Switches off at 104 40
Table 030-8: Temperature Limiter Cutoff
1
Connected in series with the defrost heater; must be replaced after tripping.
Temperature limiter (F2)
°F °C
Temperature resistance limit 158 70
Table 030-9: Temperature Limiter Cutoff
1